Banatton 1 ~ 3K-Li Online UPS Li-ion batrị 220V/230V/240V PF0.9 IEC62040 Ọkụ na-adịghị akwụsị akwụsị
Njirimara:
Oge mbufe efu
Ezi UPS ngbanwe n'ịntanetị ugboro abụọ, na-enye akụrụngwa nchebe kachasị oke mkpa site na nsogbu ịdịmma ike dị iche iche
Dabere na njikwa dijitalụ DSP
Ọganihu DSP isi njikwa dijitalụ na-eweta arụmọrụ dị elu nke ihe ntinye ike dị elu, mgbagha dị ala, na-ebunye ibu ya na ọkụ sine wave AC zuru oke.
Batrị Li-ion kwadoro
Nye ihe ruru 3x ndabere oge na nha 50%, atụnyere ngwaahịa UPS Lead-acid oge niile.
Interface njikwa kọntaktị akọrọ maka BMS
Ngwakọta kọntaktị akpọrọ akpọkọtara maka njikwa BMS bụ isi, maka njikwa chaja na mbupu ntọala na ozi BMS dị omimi.
ModBUS interface nwere BMS
Incorporated ModBUS(RS485) interface na BMS, iji nweta kpọmkwem ozi batrị (voltaji/soc/soh, wdg) maka mma UPS amụma amụma na ndabere nchekwa akara akaghị.
Chaja batrị Li-ion
Volta na-adị ugbu a, Volta na-adịgide adịgide, Na-ese n'elu mmiri, Gbanyụọ chaja steeti 4 maka batrị Li-ion, mepere emepe iji hazie omume ezi uche dị na ya maka ngwugwu batrị akọwapụtara nke ndị ahịa.
Oke ntinye ihe ntinye obosara
Ike dakọtara na ultra na eletriki gburugburu, nọrọ nke ọma na ultrawide nso mains nke 90V ~ 300V, 40 ~ 70Hz, na-ebelata ihapu batrị n'ụzọ dị egwu, ogologo ndụ batrị.
Ikike nbudata kacha mma
Ihe ruru 0.9 mmepụta ike, 50/60 Hz na-akpaghị aka, voltaji a na-ahọrọ, dabara nke ọma ụdị ngwa niile.
Genset dakọtara
Nwee ike ịrụ ọrụ na ụdị Genset dị iche iche, mgbanwe dịpụrụ adịpụ na mkpọtụ sitere na Genset, na-enye akụrụngwa ike kwụsiri ike ma dị ọcha.
Ihe ntinye ike dị elu
Ekele maka teknụzụ PFC dijitalụ na-achịkwa,> ihe ntinye ike ntinye 0.99, zere mmetọ ike nke ọma, chekwaa ego ike maka ndị ahịa.
Nhazi ntụkwasị obi
Mere na ike Glass fiber base (FR4) abụọ n'akụkụ PCB, ụlọ ọrụ na nnukwu span akụrụngwa, ukwuu melite ntụkwasị obi na obi ọjọọ gburugburu ebe obibi, ọma ventilashion na conformal mkpuchi, zere uzuzu ìgwè, melite eguzogide corrosion.
Mepee maka ịhazi ya
Dabere na njikwa siri ike yana ihe owuwu mepere emepe, ngwaahịa a nwere ike ịhazi ya ka ọ dabara mkpa nke ntinye sistemu akpaaka ma ọ bụ sistemụ nlekọta nwere ọgụgụ isi.
Nkọwapụta:
Nlereanya | 1K-Li | 1KS-Li | 2K-Li | 2KS-Li | 3K-Li | 3KS-Li | |||||||
Ike | VA/W | 1kVA / 900W | 2kVA / 1.8kW | 3kVA / 2.7kW | |||||||||
Topology | Ntugharị UPS ugboro abụọ n'ịntanetị | ||||||||||||
Usoro | Ntinye Otu Oge Ntinye Otu nkeji | ||||||||||||
Ntinye isi | Wiring | L/N+PE | |||||||||||
Ogo voltaji | 208/220/230/240VAC | ||||||||||||
Oke voltaji | 90-300VAC | ||||||||||||
Oke ugboro ugboro | 40Hz-70Hz | ||||||||||||
Ihe ntinye ike | ≥0.99 | ||||||||||||
Mmepụta AC | Wiring | L/N+PE | |||||||||||
Mpụta voltaji | 208/220/230/240VAC | ||||||||||||
Ụkpụrụ voltaji | ±1% | ||||||||||||
Ugboro mmepụta | 50/60± 4Hz(Ụdị mmekọrịta) / 50/60Hz± 0.1% (Ọsọ efu) | ||||||||||||
Waveform | Sine Wave | ||||||||||||
Ntughari (THDV%) | <2% (Ibu Ibu ahịrị) | ||||||||||||
<8% (Njikere enweghị eriri) | |||||||||||||
Ikike ibu karịrị | 100% ~ 105% na-aga n'ihu. 60Sec.@105% ~ 130% Ebugo tụrụ oke 10Sec.@130% ~ 150% Ebugo tụrụ oke 0.3Sec.@> 150% Ebugo akwadoro | ||||||||||||
arụmọrụ | Ụdị ECO | 88% | 89% | 90% | |||||||||
Ụdị batrị | 86% | 87% | 88% | ||||||||||
Batrị & chaja | Voltaji batrị enwetara | 48VDC (ndabara maka 15cell nke LiFePO4) | |||||||||||
Ike batrị | 600WH | Batrị mpụga dabere | 1000WH | Batrị mpụga dabere | 1000WH | Batrị mpụga dabere | |||||||
Oge ndabere | > 40mins @ Ibu zuru oke | > 30mins @ Ibu zuru oke | >20mins @ Ibu Ibu | ||||||||||
Ịchaji ugbu a | 4A/8A | ||||||||||||
Ịchaji voltaji | 52.8V (ndabara maka 15cell nke LiFePO4) / ahaziri dịka arịrịọ batrị siri dị | ||||||||||||
Omume chaja & Nchedo | CC.CV.Na-ese n'elu mmiri.Gbanyụọ steeti 4 3 n'elu voltaji nchedo loop, chebe interface maka ihe karịrị okpomọkụ / n'elu nrụgide gbanyụọ interface | ||||||||||||
Anụ ahụ | Ụdị chassis | RACK/ Tower (nkewapụrụ) | |||||||||||
Akụkụ Rack | 1K: 438x88(2U)X360mm1KS: 438x88(2U)X360mm | 2K: 438x88(2U)X500mm 2KS: 438x88 (2U) x360mm | 3K: 438x88(2U)X650mm 3KS: 438x88 (2U) x360mm | ||||||||||
Ụlọ elu Dimension | C1KS/C2KS: 145×220×390mm C3KS: 190×318×365mm C1k/C2k: 190×318×365mm C3K:190×318×415MM | ||||||||||||
| Ibu (Tower) | 10.8kg | 5.0kg | 16.5kg | 5.5kg | 18.0kg | 7,9kg | ||||||
Ibu (Rack) | 12.5kg | 6,5kg | 21.6 n'arọ | 6.8kg | 24.5kg | 8.2kg | |||||||
HMI | Ihe ngosi LED | Ọkwa igwe / batrị, ọkwa ibu, ọkwa batrị, Ọnọdụ ọrụ | |||||||||||
Ihe ngosi LCD nwere ihe ngosi LED | Ntinye ọkụ eletrik, ugboro ugboro, ọkwa ibu, Ọnọdụ ọrụ, Ọnọdụ ahụike | ||||||||||||
Ụkpụrụ Mkparịta ụka | 1. RS232 ọdụ ụgbọ mmiri 2. Kaadị netwọkụ: Nkwado SNMP, TCP/IP Protocol, maka nleba anya anya UPS site na Smart Phone APP, ibe weebụ, PC Monitor Software, Nkwado Server / NAS mechiri emechi. 3. Interface kọntaktị akọrọ maka njikwa BMS
| ||||||||||||
Environment na-arụ ọrụ Ntachi obi | Oke okpomọkụ | -10-50oC | |||||||||||
Iru mmiri dị n'etiti | 0-98% (na-abụghị condensing) | ||||||||||||
Acoustics Noise | <55dB @ 1 mita |
UPS Outlook:
Nlele ihu
1KS/2KS-LI Ogwe ihu
1k/2k/3K(S)-LIOgwe ihu
1K(S)/2K(S)/3K(S) -LI 2U RACK Ogwe ihu
Nlele azụ
1KS-LV-LIOgwe azụ
Ogwe azụ 2K~3K-LV-LI
1k/2k(S)-LI 2U RACKUPSOgwe azụ
3K(S)-LI 2U RACKUPSOgwe azụ
Wiring n'etiti UPS na Li-ion batrị ngwugwu
Interface kọntaktị akọrọ maka njikwa BMS
C1, C2 Kọntaktị njikwa Nchaji D1, D2 Kọntaktị njikwa ịchaji
ModBUS Interface maka BMS
Ntụtụ 1:485A, pin2: 485B, pin3-8: efu
Biko kpọtụrụ onye nnochite anya ndị ahịa maka nkọwa nzikọrịta ozi Protocol
Rịba ama:
①Ike batrị na voltaji ghe oghe maka ịhazi ya
②Akụkụ nwere ike ịdị iche maka bezel dị iche iche
③Nhazi oghere na ọnụ na azụ azụ nwere ike ịdị iche maka mba ma ọ bụ mpaghara dịka usoro siri dị
④ Nhazi ihe ndị ọzọ, bikokọntaktị ahịa onye nnọchiteanya